Tech Supply Depothome
Home  |  Contact Us  |  My Account  |  View Cart  
0 item(s) in Your Cart  
Total: $0  
 

Home?>?Ventilation Products?>?Rooms & Closets

For help selecting products, please do not hesitate to contact us at

Feel free to include any system pics, drawings, equipment descriptions and provide details like if it is a new or retro application.  We are here to help as quality products is only one part of the equation as to why CCI and TSD are the best option for your system cooling needs!


Cool Components Ceiling Vent System - Grill Assembly & Fan Unit 1-VS-CVS
Cool Components Ceiling Vent System - Grill Assembly & Fan Unit
Cool Components Ceiling Vent System - Grill Assembly & Fan Unit
Price
Retail Price: $250.00
Savings: $50.00
Your Price:
$200.00
Options, Quantity, and Purchasing
The below are options for this item - please select as desired.
Power Options - This unit ships with a US power supply
International Power Supply
Check this option if you require an international power supply (+$9.00)
help
Harsh Environment - Only required for extreme conditions
Harsh Environment Unit (+$60.00)
help


When Options and Related Items have been selected, complete the quantity desired below and click the Add to Cart button

Quantity
Related Items
The below items are not required but may be useful with this item

Enter the quantities for items you desire and click Add to Cart button above (all items will be added to the cart at one time)
Cool Components Ceiling Vent System - Rough-In Box 1-VS-CDB-CVS Cool Components Ceiling Vent System - Rough-In Box $55.00
Cool Components Ceiling Vent System Filter 1-VA-CVS-FLTR Cool Components Ceiling Vent System Filter $5.95
Cool Components Advanced Ventilation Controller 1-TC-AVC Cool Components Advanced Ventilation Controller $125.00
Advanced LT Controller - On/Off & Variable Speed 1-TC-ALT Advanced LT Controller - On/Off & Variable Speed $30.00
Cool Components Basic Temp Controller - 80 Degree (On/Off Only) 1-TC-BSC-80 Cool Components Basic Temp Controller - 80 Degree (On/Off Only) $22.50
Cool Components 4 1-VS-4FT-INS-25 Cool Components 4" Flex Tubing - 25' Insulated (Not UL Listed) $65.00
Item Description

 

Manufacturer: Cool Components
Part#: VS-CVS (formerly VS-RVS-ASBY)

This system is for very aggressively venting rooms and closets.  It has been designed to work with the home's HVAC system which is the most efficient and effective way to circulate and reprocess the hot air generated by electronic components. If for whatever reason it is not possible to connect to the HVAC system, this system can also be used to easily and effectively vent from the equipment room or closet to another area.  The system works in conjunction with the Ceiling Vent System Rough-In Box (VS-CDB-CVS) and from that box, you would typically use 4" flex pipe and let the HVAC contractor make the connection to the HVAC system.  If just venting to another area, in that area you would use either the 4x4 duct box or the 4x8 duct box (VS-WDB-HFL or HF) and also the 4" to 3" reducer (for converting the different size flex duct needed), and connect the two duct boxes.  In this scenario you would want to vent from the room or closet to a main room or hallway in the house and close to a return vent if possible so the warmer air is still reprocessed most efficiently.  If you use the 4x4 duct box, you can use the passive grills for 4x5 openings (GR-45) and if you use the 4x8 duct box, use the GR-410 or you can use a standard 4x8 HVAC grill if you wish to match the other grills in your home.

Harsh Environment Option - This unit is also available with a fans engineered with an industry leading IP68 rating for harsh environments which is ideal for outside, wet, humid or especially dirty and dusty areas.  The units are also effective in high altitudes and in extreme temperatures.  It should be noted that harsh environment does not mean better quality or longevity, just enhanced engineering and production to protect against these environmental situations.  In practical terms this means that unless truly require the added protection, there is no reason to purchase these fans.


Related Files (Click to Open/Download):

   - Ceiling Vent System Product Sheet

Features

  • Engineered To Efficiently Recirculate Hot Air from Rooms & Closets through the HVAC System or to Another Part of the Home or Office
  • Uses Rough-In Boxes for Installation During Construction which Makes Final Installation Quick and Easy
  • Utilizes DC Power System so Electricians are Not Required for the Installation
  • DC Power System Allows for Advanced Control
  • Very Low Noise with Maximum Effectiveness & Efficiency
  • Grill Assembly Can Be Painted
  • Includes Air Filter for Dust Collection
  • Includes 600mA Variable Voltage Power Supply (PS-600) and a 6' Extension Cable (PA-EC)
  • Available with Harsh Environment Fans (IP68 rated)

General Specifications
         
Dimension Grill Housing:  L - 12 3/4 x W - 12 3/4 x D 2 1/2 (32.3cm x 32.3 x 6.5)
Dimension  Fan Unit:        L - 10 x W - 10 x D 1 1/8 (25.4cm x 25.4 x 3)
Construction:                     Grill & Fan Bracket - Heavy Gauge Steel (Grill - White / Fan Housing - Black)
Cooling System:                Brushless 92mm Levitation Fans w/Specialty Bearing System (Est. 60,000hr)
Air Flow:                           ~80-160CFM
      
Power Specifications
 
Noise:                               Dependent on Settings (Can be run quietly)
Power Connection:             2-Pin FastWire System (Ensure proper polarity)
Voltage:                            7 to 9V DC for Normal Operation or 9 to 12V for More Aggressive Cooling
Current:                             350mA at 12V DC
 

 
While most people believe that the heat generated by components is undesirable, it is a matter of perspective. It can be damaging to electronic equipment but, in the winter, most regions pay good money to heat their homes and even when the weather is milder and we seek cooler temperatures (air conditioning). The entire purpose of the HVAC system is to take warmer air and convert it to cooler air.  It may not make sense to increase the ambient temperature of the incoming air, but it is much easier for the HVAC system to 'reprocess' air that is simply heated, or really just warm by most standards.  For this reason, you never want to vent outside of the home - when venting outside, that air is often times replaced by air from the attic (through recessed lighting or other penetrations) or from outside where the air can be hot, humid, smelly...
Review this item
Email this page to a friend

Shop with confidence. This site is secured by ComodoSSL.

RapidSSL
   
This website and its contents are the exclusive intellectual property of Tech Supply Depot and the manufacturers contained herein and, as such, are protected by copyright and trademark laws. Images, photographs, descriptions, text and articles on this website may not be copied, reproduced, duplicated, sold or otherwise exploited for any commercial purpose without the express written permission of Tech Supply Depot. All rights reserved.